A cryogenic capillary pumped loop (CPL) has been developed, designed, fabricated and successfully demonstrated by test. Using no moving parts, the novel device is able to start from a supercritical state and cool a remote dissipation source to 80-90K. Design studies were conducted for integration requirements and component design optimization and prototype units were designed, fabricated and successfully tested with excellent results.

In recent years, loop heat pipe (LHP) technology has transitioned from a developmental technology to one that is flight ready. The LHP is considered to be more robust than capillary pumped loops (CPL) because the LHP does not require any preconditioning of the system prior to application of the heat load, nor does its performance become unstable in the presence of two-phase fluid in the core of the evaporator. However, both devices have a lower limit on input power: below a certain power, the system may not start properly.

The loop heat pipe (LHP) is known to have a lower limit on input power. Below this limit the system may not start properly creating the potential for critical payload components to overheat. The LHP becomes especially susceptible to these low power start-up failures following diode operation, intentional shut-down of the device, or very cold conditions. These limits are affected by the presence of adverse tilt, mass on the evaporator, and noncondensible gas in the working fluid.