The loop heat pipe (LHP) is known to have a lower limit on input power. Below this limit the system may not start properly creating the potential for critical payload components to overheat. The LHP becomes especially susceptible to these low power start-up failures following diode operation, intentional shut-down of the device, or very cold conditions. These limits are affected by the presence of adverse tilt, mass on the evaporator, and noncondensible gas in the working fluid.
This paper describes the application of the general purpose SINDA/FLUINT thermohydraulic analyzer to the modeling of vapor compression (VC) cycles such as those commonly used in automotive climate control and building HVAC systems. The software is able to simulate transient operation of vapor compression cycles, predicting pressures, coefficients of performance, and condenser/evaporator liquid positions in a closed two-phase system with a fixed fluid charge.